Ferreux, Laurent; Bouchard, Jacques, E-mail: laurent.ferreux@cea.fr2016
AbstractAbstract
[en] In this new approach, the active shielding of a low level spectrometer is monitored by an extendable dead time used as an “extendable GATE” signal. This concept is directly inspired from the live-timed anti-coincidence system implemented at LNE-LNHB (MTR2 modules). This allows a significant reduction in the cost and complexity of the system since several electronic modules are replaced by only one module dedicated specifically to this type of experiment. Settings of this new approach are detailed and results are discussed. - Highlights: • Low-level gamma spectrometry system for environmental monitoring. • System based on the extendible dead-time and live-time. • Improvement by a factor of 2 on the integral background count-rate. • Improvement by a factor of 5 on the 511 keV peak.
Primary Subject
Source
20. international conference on radionuclide metrology and its applications; Vienna (Austria); 8-11 Jun 2015; S0969-8043(15)30314-6; Available from http://dx.doi.org/10.1016/j.apradiso.2015.11.095; Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Literature Type
Conference
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue