Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.02 seconds
AbstractAbstract
[en] This research thesis reports the study of direct contact evaporator in which the secondary liquid is water, and the primary liquid is the gilotherm RD (an organic oil made of a mixture of alkylbenzenes). After a bibliographical study on the differences between fluid boiling modes, and on the overheating process, the author reports an experimental observation of these phenomena by comparing the behaviour of three pairs of fluids: water drops in gilotherm, pentane drops in water, and freon 113 drops in water. Then, he focuses on the operation of a water/gilotherm evaporator to identify the key parameters which govern its behaviour. A modelling of this exchanger then confirms the influence of the different parameters, as well as the order of magnitude of experimental performance. The modelling is then extended to counter-current exchangers, and then to those using other pairs (volatile fluid/continuous fluid). This allows the estimated performance to different systems to be compared
[fr]
Cette etude concerne un echangeur a contact direct liquide, liquide-vapeur. Elle s'interesse, dans un premier temps, aux differents modes d'ebullition d'une goutte liquide immergee dans un autre liquide, du point de vue theorique et experimental. Le degre de surchauffe, et donc les performances de l'echangeur, dependent fortement du mode d'ebullition. Dans un deuxieme temps, l'etude est consacree au fonctionnement d'un echangeur a co-courant, utilisant de l'eau dispersee dans du gilotherm. La modelisation de cet echangeur permet de retrouver avec une bonne approximation les caracteristiques et les performances observees, puis de simuler son fonctionnement a contre-courant ainsi qu'avec d'autres couples et liquides (pentane ou freon 113 disperses dans l'eau). On peut ainsi dimensionner et optimiser un evaporateur a contact direct utilisant n'importe quel couple de liquides. (auteur)Original Title
Etude de l'evaporation en contact direct d'un liquide disperse dans un autre liquide non miscible chaud: modelisation d'un evaporateur a contact direct
Primary Subject
Source
28 Mar 1986; 247 p; 45 refs.; Available from the INIS Liaison Officer for France, see the 'INIS contacts' section of the INIS-NKM website for current contact and E-mail addresses: http://www.iaea.org/inis/Contacts/; Also available from Bibliotheque de Sciences, 915 avenue Centrale 38400 Saint Martin d'Heres (France); Energetique Physique
Record Type
Report
Literature Type
Thesis/Dissertation
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue