[en] Measurement of lead equivalent thickness for ionizing radiation exposure room wall shall be performed as stated in Malaysian Standard MS 838. A few numbers of sample blocks with different mixture of barium plaster compositions based and varies certain thickness as a shielding material for exposure room wall belong to a local company were tested by using Cs-137, Co-60 and Am-241 with different activities . Radiations passed through the samples were detected with calibrated survey meter. The distance between radiation source and the detector is about 40 cm. Lead uniformity test on the samples was also determined at three labeled points on the samples. Lead equivalent thicknesses for the samples were evaluated based on a calibration graph that was plotted with lead sheets and with the radiation sources. Results shown that lead equivalent thickness for the samples with same actual physical thickness represent different values for different sources. (author)
Primary Subject
Source
2016; 6 p; R&D Seminar 2016: Research and Development Seminar 2016; Bangi (Malaysia); 8-10 Nov 2016; Also available in Malaysian Nuclear Agency Document Delivery Center by email: mohdhafizal@nuclearmalaysia.gov.my; Oral presentation