Nakanishi, Motohiro; Shibatani, Saori; Akiyama, Yoko; Nishijima, Shigehiro; Mishima, Fumihito, E-mail: nakanishi@qb.see.eng.osaka-u.ac.jp2017
AbstractAbstract
[en] One of the factors of deterioration in thermal power generation efficiency is adhesion of the scale to inner wall in feed-water system. Though thermal power plants have employed All Volatile Treatment (AVT) or Oxygen Treatment (OT) to prevent scale formation, these treatments cannot prevent it completely. In order to remove iron oxide scale, we proposed magnetic separation system using solenoidal superconducting magnet. Magnetic separation efficiency is influenced by component and morphology of scale which changes their property depending on the type of water treatment and temperature. In this study, we estimated component and morphology of iron oxide scale at each equipment in the feed-water system by analyzing simulated scale generated in the pressure vessel at 320 K to 550 K. Based on the results, we considered installation sites of the magnetic separation system. (paper)
Source
Available from http://dx.doi.org/10.1088/1742-6596/897/1/012020; Country of input: International Atomic Energy Agency (IAEA)