AbstractAbstract
[en] To improve the efficiency of a cryocooler, it is vital to improve the regenerator. In general, the heat capacity of materials decreases as temperature decreases. Thus, when temperature is below 50 K, lead spheres are often used as a regenerator material. However, the pressure drop through a sphere regenerator is larger than that through a screen regenerator. To overcome this dilemma, a new, low pressure loss tin-plated screen is proposed. A comparison test was performed with a two-stage GM cryocooler by replacing part of the first stage regenerator material, bronze screens with tin-plated screens. Compared to a regenerator filled with bronze screens, the cooling capacity of the first stage increased by about 14% at 40 K and 90% at 30 K with such tin-plated screens. The ratio of the wire diameter before and after the deposition was also optimized. An optimum cooling capacity of 53.5 W at 40 K was obtained at a diameter ratio of about 1.4. The detailed experimental results are reported in this paper. (paper)
Primary Subject
Source
26. international cryogenic engineering conference; New Delhi (India); 7-11 Mar 2016; International cryogenic materials conference 2016; New Delhi (India); 7-11 Mar 2016; Available from http://dx.doi.org/10.1088/1757-899X/171/1/012076; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Literature Type
Conference
Journal
IOP Conference Series. Materials Science and Engineering (Online); ISSN 1757-899X;
; v. 171(1); [5 p.]

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue