Thoker, S.H.; Bari, W.; Satyanarayana, B.; Shinde, R.R.; Majumder, G., E-mail: shamsulthoker@gmail.com2019
AbstractAbstract
[en] As part of detailed optimization studies on Resistive Plate Chambers (RPCs) to be deployed in huge numbers in the INO-ICAL experiment, effects of integration time on the dispersion of the induced charge as well as position resolution of a prototype RPC was studied. Two, G10 based pickup panels of strip widths 5 mm and 3 mm were used in these studies. A double Gaussian function was used to fit the dispersion of the induced charge on the strips due to passage of cosmic ray muons through the RPC.
Primary Subject
Source
Available from http://dx.doi.org/10.1088/1748-0221/14/05/P05021; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Journal of Instrumentation; ISSN 1748-0221;
; v. 14(05); p. P05021

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue