[en] A search for resonant absorption of solar axions by Tm nuclei was carried out. A newly developed approach involving low-background cryogenic bolometer based on TmAlO crystal was used that allowed for significant improvement of sensitivity in comparison with previous Tm based experiments. The measurements performed with 8.18 g crystal during 6.6 days exposure yielded the following limits on axion couplings: |g(g + g) ≤ 1.44 × 10 GeV and |g(g + g) ≤ 2.81 × 10.
Primary Subject
Secondary Subject
Source
Available from: http://dx.doi.org/10.1140/epjc/s10052-020-7943-5; AID: 376
Record Type
Journal Article
Literature Type
Numerical Data
Journal
European Physical Journal. C, Particles and Fields (Online); ISSN 1434-6052;
; v. 80(5); p. 1-7