[en] Due to high thermal neutron absorption cross-section, boron (B) content is a binding specification for nuclear grade graphite. Reliable analytical methods are essential to determine boron at trace to ultra-trace levels. Analytical Chemistry Division, Bhabha Atomic Research Centre, India has prepared an in-house graphite reference material (GRM). A Charged particle activation analysis methodology has been developed for quantification of B in graphite matrix. Detection limit for boron using this methodology is 1.4 mg kg-1. This in-house GRM can be used for quantification of B in unknown graphite samples, validating existing analytical methods and for the development of new analytical methods. (author)
Primary Subject
Source
43 refs.
Record Type
Journal Article
Journal
Journal of Radioanalytical and Nuclear Chemistry; ISSN 0236-5731;
; CODEN JRNCDM; v. 328(1); p. 33-38