Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.021 seconds
AbstractAbstract
[en] Automatic translation: Component test cycle (KVK): In 1989 the KVK achieved an availability of 97%. The Total operating time is 19407 hours, of which 7331 hours above 900 ° C and 11434 hours above 700 ° C. During the operating phase, the test instrumentation and the data acquisition systems were looked after. The second test phase for the NWA cooler began on 01/19/89 and ended on 02/22/89. The NWA cooler was partially open Retrofitted finned tubes and together with the one in September 1989 investigated built-in core connection from mid-November 1989. On the monitor samples that were taken from the KVK in 1988, metallographic examinations were carried out.
[de]
Komponenten-Versuchskreislauf (KVK): Der KVK erreichte 1989 eine Verfügbarkeit von 97 %. Die Gesamtbetriebszeit beträgt 19407 Stunden, davon 7331 Stunden oberhalb 900°C und 11434 Stunden oberhalb 700°C. Während der Betriebsphase erfolgte die Betreuung der Versuchsinstrumentierung und der Datenerfassungssysteme. Die zweite Versuchsphase für den NWA-Kühler begann am 19.01.89 und endete am 22.02.89. Der NWA-Kühler wurde teilweise auf Rippenrohre umgerüstet und gemeinsam mit dem im September 1989 eingebauten Core—Anschluß ab Mitte November 1989 untersucht. An den Monitorproben, die 1988 aus dem KVK entnommen wurden, erfolgten metallografische Untersuchungen.Original Title
Forschungs- und Entwicklungsprogramm zur Protypanlage Nukleare Prozesswärme. Jahresbericht 1989. Entwicklungsarbeiten zum Komponenten- Versuchskreislauf, zur Komponentenerprobung und zum Nuklearen Wärmeerzeugungssystem
Primary Subject
Source
1990; 118 p; Country of input: International Atomic Energy Agency (IAEA); Document from Juelich Preservation Project; Refs., figs., tabs.
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue