[en] As part of the conversion programme of the Munich MP-Tandem accelerator a Pelletron charging system has been installed and high voltage tests have been performed without acceleration tubes. Preliminary experience and test results are reported. In pure SF6 the Pelletron chains delivered the guaranteed charging current of 100 μA per chain at 14 MV terminal voltage. A maximum terminal voltage of 16.1 MV was achieved at an SF6 pressure of 0.76 MN/m2. Earlier tests were carried out with a 30% SF6/70% N2 mixture at pressures up to 1.2 MN/m2. The comparison indicates, that in pure SF6 spark damage of componenets is less likely than in an SF6 mixture. (Auth.)
Primary Subject
Record Type
Journal Article
Journal
Nuclear Instruments and Methods; v. 137(1); p. 19-21
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume