Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.014 seconds
Grishkevich, Ya.V.; Poze, D.; Ryuger, Kh.; Tryuchler, K.; Peter, G.; Shvind, A.
Joint Inst. for Nuclear Research, Dubna (USSR)1975
Joint Inst. for Nuclear Research, Dubna (USSR)1975
AbstractAbstract
[en] Theory and constructional layout of a pulse transformer is given by which it is possible to drive a large Blumlein-line as a high-voltage pulse generator for a streamer chamber. The transformer is capable of generating voltage pulses with an amplitude of 500 kV at a load of 1000 pF. The rise time of the pulse is 300 nsec. The stability of the pulse amplitude in the streamer chamber is +-1.5% and the jitter of the pulse delay time is +- 10 nsec
Original Title
Sistema vysokovol'tnogo pitaniya strimernoj kamery na baze impul'snogo transformatora
Source
1975; 21 p; 7 refs.; 2 tables; 14 figs.; submitted to the journal Instrum. Exp. Tech.
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume