Tharin, D.W.; Beals, R.A.; Colberg, R.D.
Du Pont de Nemours (E.I.) and Co., Aiken, S.C. (USA). Savannah River Plant1977
Du Pont de Nemours (E.I.) and Co., Aiken, S.C. (USA). Savannah River Plant1977
AbstractAbstract
[en] A D2O tracer test was conducted in tank 21 by continuously, vaporizing D2O into the vapor space for one month. During tracer addition, condensate from the vapor space was analyzed and found to have a D2O content as high as 8.8 times natural occurrence. Concurrently, D2O concentration in the sump increased to 1.5 times natural occurrence. The presence of tracer in the sump with the short-response time is considered conclusive evidence that there is communication with the vapor space, and that condensation from the vapor space is the source of low level contamination in the sump
Primary Subject
Source
Jan 1977; 17 p; Available from NTIS., PC A02/MF A01