Rosal, E.R.; Conway, C.E.; Krepinevich, M.C.
Westinghouse Electric Corp., Pittsburgh, Pa. (USA)1977
Westinghouse Electric Corp., Pittsburgh, Pa. (USA)1977
AbstractAbstract
[en] The FLECHT Low Flooding Rate Tests were conducted in an improved original FLECHT Test Facility to provide heat transfer coefficient and entrainment data at forced flooding rates of 1 in./sec. and with electrically heated rod bundles which had cosine and top skewed axial power profiles. The top-skewed axial power profile test series has now been successfully completed and is here reported. For these tests the rod bundle was enclosed in a low mass cylindrical housing which would minimize the wall housing effects encountered in the cosine test series. These tests examined the effects of initial clad temperature, variable stepped and continuously variable flooding rates, housing heat release, rod peak power, constant low flooding rates, coolant subcooling, hot and cold channel entrainment, and bundle stored and generated power. Data obtained in runs which met the test specifications are reported here, and include rod clad temperatures, turn around and quench times, heat transfer coefficients, inlet flooding rates, overall mass balances, differential pressures and calculated void fractions in the test section, thimble wall and steam temperatures, and exhaust steam and liquid carryover rates
Original Title
PWR
Primary Subject
Secondary Subject
Source
May 1977; v p; Westinghouse Electric Corp., Pittsburgh, PA
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue