Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.015 seconds
AbstractAbstract
[en] An instrumentation system (Aging Integrator) has been developed to provide more precise control of the heat-treatment process used on uranium-0.75 wt.% titanium alloy material. The Aging Integrator calculates the integral of a predetermined aging function to control the aging period in the heat-treatment process. This control was employed to compensate for discrepancies caused by variations in heatup times, furnace-control fluctuations, and disagreement as to the temperature at which aging actually starts. Although the Aging Integrator hardware has been installed and satisfactorily tested on a production-area furnace, sufficient data to estimate a statistically sound aging integration function will not be available for approximately one year
Primary Subject
Secondary Subject
Source
Dec 1977; 19 p; Available from NTIS., PC A02/MF A01
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume