[en] The system study concludes that, after a sodium-water reaction in an LMFBR power plant, the hot sodium circulation process is an economical and practical method of removing the SWRP from the IHTS. It is proposed that the impure sodium produced by the hot sodium circulation process be purified by a special fast cleanup cold trap design which is shown herein. The hot sodium circulation process, using the special fast cleanup cold trap, is shown to save a significant amount of downtime during the life of each LMFBR plant. A development program for the recommended process is included