Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.019 seconds
AbstractAbstract
[en] Systems analyses have been performed in order to determine the parameter ranges for economic operation of equilibrium commercial fusion power plants using noncircular tokamak reactors. The results of these studies show that: (1) Neutron wall loadings over 2 megawatts per square meter may be unnecessary for economic tokamak operation. (2) Electrical power levels beyond 1000 MW(e) are not required. In fact, power levels as low as 100 MW(e) may be acceptable. (3) Total beta values of 10 to 12 percent are adequate. (4) Duty cycles as low as 50 percent have only a small effect on plant economics. (5) An acceptable first wall lifetime is 15 MW-yr per square meter
Primary Subject
Source
Apr 1978; 7 p; 3. meeting on the technology of controlled thermonuclear fusion; Santa Fe, NM, USA; 9 - 11 May 1978; CONF-780508--19; Available from NTIS., PC A02/MF A01
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume