AbstractAbstract
[en] In this paper, it was introduced that the domestic source-less efficiency calibration software Gamma-Clib(shorter form GC) about its parameters, and the application of GC on a set of HPGe Gamma Spectrometer to obtain the detection efficiency calibration curve. In the experiment, 4 point radiations and 2 cylinder body radiations which can be traceable were used to calibrate the same HPGe detection system. By comparing the results got from two methods, it shows that the deviations of point source were -0.08%∼5.64%, and the deviations of cylinder body source were 3.95%∼16.94%. The results show that GC can be used to calculate the efficiency of HPGe detection system, and can be a of Gamma Spectrometer analysis. (authors)
Primary Subject
Source
7 figs., 1 tab., 4 refs.
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 35(8); p. 797

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The well-type HPGe detector is an important equipment to measure weak radioactivity, its efficiency hardly depends on the counting geometry. So, the efficiency must be calibrated using the same nuclide firstly while determining the nuclide activity generally. We calibrate the peak and total efficiency of well-type HPGe detector by using a series single gamma nuclides and research the true coincidence summing effect. The efficiency curve are extended and checked using the known activity sources 60Co, 134Cs and 133Ba. (authors)
Primary Subject
Source
3 figs., 5 tabs., 3 refs.
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 28(3); p. 4810485

Country of publication
ALKALINE EARTH ISOTOPES, BARIUM ISOTOPES, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CESIUM ISOTOPES, COBALT ISOTOPES, COUNTING TECHNIQUES, DAYS LIVING RADIOISOTOPES, DETECTION, ELECTRON CAPTURE RADIOISOTOPES, EVEN-ODD NUCLEI, GE SEMICONDUCTOR DETECTORS, HOURS LIVING RADIOISOTOPES, INTERMEDIATE MASS NUCLEI, INTERNAL CONVERSION RADIOISOTOPES, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, MEASURING INSTRUMENTS, MINUTES LIVING RADIOISOTOPES, NUCLEI, ODD-ODD NUCLEI, RADIATION DETECTION, RADIATION DETECTORS, RADIOISOTOPES, SEMICONDUCTOR DETECTORS, STANDARDS, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The Beijing Spectrometer (BES) is a large scale magnetic spectrometer for Beijing electron-positron collider. The magnetic field stability of BES is very important for data quality. At present, there are two methods of measuring magnetic field on BES. They are NMR and Hall magnetic field measurement systems
Secondary Subject
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 18(2); p. 154-158

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The coupling model of cable was introduced. Finally, the calculation of results were given and compared with the experiment
Primary Subject
Secondary Subject
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 20(2); p. 138-141

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] A low-power pulse amplitude discriminator is described. The discriminator circuit is mainly composed of an integrated voltage comparator, MAX921, and owns the characters of very low-power and low operating voltage
Primary Subject
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 20(3); p. 240-241

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The author sets up the two dimensional Electric Field Integral Equation (EFIE) in the time domain. The way of solving EFIE from one dimension to two by the method of moment is developed, and the formula that can be used in the calculation is given. Finally, a calculation results for SGEMP simulator were presented
Primary Subject
Secondary Subject
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 20(1); p. 51-55

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] A new mode of Gas Electron Multiplier (GEM) is introduced. Its gain property is studied using a MWPC coupled with the GEM, under various Ar/CO2 ratio. The GEM gain of 94 could be reached
Primary Subject
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 20(5); p. 350-353

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The author introduces possibility for measuring the paper basis weight (mass thickness per unit area) by low energy γ-ray backscattering techniques. The relation between the paper basis weight and the intensity of low energy γ-ray backscattering has been established. A measuring device has been completed and its measuring results are analysed
Primary Subject
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 21(2); p. 148-150

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] A design of clock measurement module is introduced. This VXIbus module is implemented based on techniques of high speed data acquisition and digital signal processing, its sampling rate is 500 Msps and time resolution is 2 ns
Primary Subject
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 21(1); p. 14-17

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The software designing method and process of Beam Diagnostic system are discussed, the interface design of the system is also described. The new system has many advantages than original in speed, convenience and stability
Primary Subject
Secondary Subject
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 19(4); p. 287-291

Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
1 | 2 | 3 | Next |