A circuit design for front-end read-out electronics of beam homogeneity measurement
AbstractAbstract
[en] It introduces a circuit design of beam homogeneity measurement for heavy ion beam in the monitoring needs, which convert multichannel weak current from 10 pA to 100 nA of the output of parallel plate avalanche counter (PPAC) for large area with sensitive two-dimensional position to voltage signal from -2 V to -20 mV by current-voltage-converter (IVC) circuit which composed of T-feedback resistor networks, combined with data acquisition and processing system realized the beam homogeneity measurement in heavy ion tumor therapy of the Institute of Modern Physics. Experiments have shown that the circuit with speed and high precision. This circuit can be used for read-out of the beam for the Multiwire Proportional Chamber, Faraday Cup and other weak current sources. (authors)
Primary Subject
Source
9 figs., 7 refs.
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934;
; v. 31(6); p. 646-651

Country of publication
Descriptors (DEI)
ACCURACY, BEAM CURRENTS, BEAM MONITORING, DATA ACQUISITION SYSTEMS, DATA PROCESSING, DESIGN, ELECTRIC CURRENTS, ELECTRIC POTENTIAL, EXTERNAL BEAM RADIATION THERAPY, FARADAY CUPS, HEAVY IONS, ION BEAMS, MONITORING, MULTIWIRE PROPORTIONAL CHAMBERS, NEOPLASMS, POSITION SENSITIVE DETECTORS, READOUT SYSTEMS, RESISTORS, SIGNALS