Published 1994 | Version v1
Miscellaneous

Initial investigations of dose distribution patterns for an industrial electron accelerator

  • 1. Inst. fuer Verfahrenstechnik der Bundesforschungsanstalt fuer Ernaehrung, Karlsruhe (Germany)

Description

A newly developed accelerator for electrons in the dose range of up 10 mev at 10 kw performance replaces a similar type of accelerator that has been in use during the past 25 years. It is characterized by some decisive technical changes. The ray, rather than moving from one point to the next, is now distributed over the merchandise for the duration of an impulse. In the direction of conveyance, irradiation is carried out on successive fields as was done formerly. As the duration of impulse is no longer than 12 μs, some problems arose in respect of operation and measuring techniques: the time distribution of microwave energy or rays emitted during the individual impulses has a bearing on the dose distribution pattern at a right angle to the direction of transport in both the superficial and deep layers of the merchandise. Some of the initial measuring results are represented here. The accelerator's operational parameters were then so adjusted that a largely homogeneous dose distribution was achieved throughout. (orig.)

Abstract (German)

Ein neuer Beschleuniger fuer Elektronen bis zu 10 MeV bei 10 kW Leistung ersetzt einen aehnlichen Beschleuniger, der 25 Jahre in Betrieb war. Dabei ergaben sich wesentliche technische Veraenderungen: der Strahl wird nicht mehr punktweise ueber das Gut gefuehrt, sondern waehrend der Dauer eines Impulses ueber die Gutsbreite verteilt; in Foerderrichtung erfolgt die Bestrahlung streifenweise wie zuvor. Da die Impulsdauer nur 12 μs betraegt, ergaben sich betriebs- und messtechnische Probleme: die zeitliche Verteilung der Mikrowellenenergie bzw. des Strahlstromes waehrend des Impulses beeinflusst die Dosisverteilung quer zur Transportrichtung sowohl an der Oberflaeche wie in der Tiefe des Gutes. Hierzu werden erste Messungen vorgestellt. Durch Anpassung von Betriebsparametern des Beschleunigers konnte eine insgesamt moeglichst homogene Dosisverteilung erreicht werden. (orig.)
Part of:
4. German conference on food irradiation. Assessment - methods - detection

Additional details

Additional titles

Original title (German)
Erste Untersuchungen zur Dosisverteilung bei einem industriellen Elektronen-Beschleuniger

Publishing Information

ISBN
3-89254-213-9
Imprint Title
4. German conference on food irradiation. Assessment - methods - detection
Imprint Pagination
184 p.
Journal Volume
5/1994
Series
SozEp-Hefte.
Journal Page Range
p. 89-91.
ISSN
0175-4246

Conference

Title
4. German conference on food irradiation.
Original Conference Title
4. Deutsche Tagung Lebensmittelbestrahlung - Beurteilung, Technik, Nachweis
Dates
6-7 Apr 1994.
Place
Hamm (Germany).

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
27011014
Subject category
S07: ISOTOPES AND RADIATION SOURCES; S60: APPLIED LIFE SCIENCES; S07: ISOTOPES AND RADIATION SOURCES;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
EQUIPMENT; FOOD; INDUSTRIAL PLANTS; LINEAR ACCELERATORS; RADIOPRESERVATION
Descriptors DEC
ACCELERATORS; IRRADIATION; PRESERVATION

Optional Information

Notes
Imprint:4. Deutsche Tagung: Lebensmittelbestrahlung. Beurteilung - Technik -Nachweis.