Published 1993 | Version v1
Book

Microtron-injector for booster synchrotron of SR facility

  • 1. Centre for Advanced Technology, Indore (India)

Description

This paper describes the design features of a 20 MeV, 30 mA microtron to be used as injector to the 700 MeV booster synchrotron of synchrotron radiation (SR) facility. The microtron was designed and developed at Centre for Advanced Technology (CAT). All the components and systems were made indigenously except microwave components such as a 5.0 MW klystron and circulators which were imported. The paper also highlights the microtron development project at CAT. (author). 1 fig

Part of:
Synchrotron radiation sources

Additional details

Publishing Information

Publisher
Centre for Advanced Technology.
Imprint Place
Indore (India)
Imprint Title
Synchrotron radiation sources [Proceedings of the international conference]
Imprint Pagination
431 p.
Journal Page Range
p. 181-184.

Conference

Title
International conference on synchrotron radiation sources.
Dates
3-6 Feb 1992.
Place
Indore (India).