Published November 2016 | Version v1
Book

Performance of Panasonic ZP-1460 electronic personal dosemeter under exposure conditions likely to be found at Fukushima Daiichi nuclear power plant

  • 1. Japan Atomic Energy Agency, Sector of Decommission and Radioactive Waste Management, Nuclear Fuel Cycle Engineering Laboratories, Tokai, Ibaraki (Japan)

Description

A study on the performance of the Panasonic ZP-1460 electronic personal dosemeter, the model used in the aftermath of the Fukushima Daiichi nuclear power plant accident in March 2011, was conducted under actual exposure situations likely encountered in the plant. The tests pertained to (1) the dose rate response over dose rates >100 mSv/h and (2) the angular response on an anthropomorphic phantom exposed to the rotational and isotropic irradiation geometries. The test results confirmed that the dosemeter provides Hp(10) as a reasonably close estimate of the effective dose for any exposure geometries. The dosemeter response data evaluated in this study can be utilized for converting dosemeter readings to the absorbed dose to any organs and tissues for epidemiologic purposes. (author)

Availability note (English)

Available from http://dx.doi.org/10.7566/JPSCP.11.070008
Part of:
Proceedings of international symposium on radiation detectors and their uses (ISRD2016)

Additional details

Identifiers

Publishing Information

Publisher
Physical Society of Japan
Imprint Place
Tokyo (Japan)
ISBN
978-4-89027-115-3
Imprint Title
Proceedings of international symposium on radiation detectors and their uses (ISRD2016)
Imprint Pagination
[293 p.]
Journal Page Range
p. 070008.1-070008.6

Conference

Title
International symposium on radiation detectors and their uses
Acronym
ISRD2016
Dates
18-21 Jan 2016
Place
Tsukuba, Ibaraki (Japan)

Optional Information

Notes
8 refs., 4 figs. Imprint:JPS Conference Proceedings Vol. 11