Published February 1996 | Version v1
Book

Case histories of failures in heat exchangers experience of Nuclear Power Corporation

  • 1. Nuclear Power Corporation of India Ltd., Bombay (India)

Description

Heat exchanger tubes are important components of nuclear power stations, whether they are part of the primary heavy water loop or of light water secondary loops. Exchanger tube failure can trigger plant outages and cause significant economic losses. In some of these exchangers, failure of tubes degrades one of the multiple protective layers guarding against accidental release of radioactivity to the environment and hence there are stringent requirements limiting leakage. Various tube degradation mechanisms have been identified during pre-service (PSI) and in-service (ISI) and during manufacturing stage inspections. Each case has been analysed in detail and corrective actions, appropriate to the occasion, have been implemented. Remedial actions have included design changes, material changes, changes to manufacturing and inspection methods, changes to operating parameters in addition to the obvious tube plugging recommendations. A few selected cases are detailed in this paper. 1 fig., 1 ill

Part of:
Symposium on heat exchangers

Additional details

Publishing Information

Publisher
Indira Gandhi Centre for Atomic Research.
Imprint Place
Kalpakkam (India)
Imprint Title
Symposium on heat exchangers
Imprint Pagination
457 p.
Journal Page Range
p. X.1-1-X.1-7.

Conference

Title
Symposium on heat exchangers.
Dates
14-16 Feb 1996.
Place
Kalpakkam (India).

Optional Information

Notes
Imprint:(EN).