Description

Four Plates were irradiated in HFR Petten at a maximum surface heat fluxes of 140 and 250 W.cm-2 for enrichments of 20% and 35%, respectively. The experiment was stopped after only two cycles after failure of the two 35%- enriched plates. Analysis of postirradiation examinations and the evaluation of the experiment operating conditions have established high cladding temperature as the root-cause of the failure. (author)

Files

9wx86-ty488.pdf

Files (194.7 kB)

Name Size Download all
md5:d8864beb41122157b3625991228e51af
194.7 kB Preview Download
Part of:
ENS RRFM 2003. Transactions

Additional details

Publishing Information

Imprint Title
ENS RRFM 2003. Transactions
Imprint Pagination
p. 72-80
Report number
INIS-XA--652

Conference

Title
7. international topical meeting on research reactor fuel management
Dates
9-12 Mar 2003
Place
Aix-en-Provence (France)

Optional Information

Notes
10 refs., 11 figs., 4 tabs.